Solutions · masonry or concrete lift shafts
Fixing guide rails and landing doors to uneven shaft walls
On irregular or out-of-square walls Panev brackets are adjusted on site: the articulated joint takes up the angle (± 7° / ± 8° for landing doors), the slotted holes let the fixing move, and the SG joining bracket slides on its support to cover the distance between wall and guide rail.
The problem on site
Along the lift shaft, cast-in-place concrete often has protrusions and recesses, and the wall is not always square to the component to be fixed. Traditional brackets do not adapt easily, forcing the installer into on-site modifications.
The Panev system is perforated, hinged and slotted: designed to adapt to irregular, out-of-plumb masonry and walls with rebar.
Which adjustment for which wall
| Condition on site | How it is taken up | System |
|---|---|---|
| Wall not square to the landing door | Articulated joint: angular adjustment of ± 8° (65 series) or ± 7° (45 and 37 series) | A plate + B bracket |
| Varying distance between wall and counterweight guide rail | The SG joining bracket slides on the support within the extension range of the configuration, for example 45 – 155 mm for SU 220 160 with SG 80 150 | SU or SC support + SG |
| Irregular wall, fixing to be moved off-centre | Offset base, for more freedom of positioning | SD support + SG |
| Corner walls of the shaft | Fixing directly to the wall with an adjustable rigid arm | SN 60 65, SN 65 200 and BRACCIO 160 190 |
| Projection outside the standard sizes | Projection “A” defined on the site’s shop drawing | SC 50 170 support |
Mounting in six steps
The articulated bracket is installed with three tools: a hammer drill, spanners and a spirit level.
-
Marking and drilling
Mark the position on the wall and drill with the hammer drill, using the slotted holes of the fixing element.
-
Fixing to the wall
Fix the fixing element with the anchors and, before tightening, check with the spirit level that it is vertical.
-
Setting the angle
Turn the support element about the articulated joint to take up walls that protrude or recede.
-
Locking
Tighten the clamping element in the slot to lock the set angle permanently.
-
Adjusting and cutting
Adjust the lengthwise position of the support and, if necessary, cut it to size as the mounting requires.
-
Fixing the component
Connect the component — sill, door operator or guide rail — to the connection holes and check the final alignment with the spirit level.
Summary for qualified installers: the installation drawings in the technical catalogue and the design of the installation prevail. PDF catalogue · p. 10 · The articulated bracket is patented: patent details
Fitted to real walls
Photos from building sites: Panev brackets on uneven concrete and out-of-square walls, adjusted on the spot.
Uneven walls: FAQ
How are counterweight guide rails fixed to irregular walls?
With an adjustable support (SU, SD or SC) and the SG joining bracket: the support is fixed to the wall and the joining bracket slides on it within the extension range given for each configuration, with a 35 mm overlap flap. The SD support has an offset base, for more freedom of positioning on irregular walls.
How is a wall that is not square to the landing door taken up?
With the articulated joint of the landing door brackets: the support element turns relative to the one fixed to the wall, by ± 8° on the 65 series and ± 7° on the 45 and 37 series, and a clamping element locks the angle once it is set.
Which tools are needed for mounting?
Three: a hammer drill, spanners and a spirit level.
What if the size I need is not on the price list?
It is made to order: the projection “A” of the SC 50 170 support is defined on the site’s shop drawing. Send the drawing or the measurements to info@panevascensori.it and receive a quote for the job.
The bracket families
Direct ordering by email
No cart, no registration: pick the codes from the price list and send your order by email. We reply with an order confirmation or a quote.
Order by email